skip to main content


Search for: All records

Creators/Authors contains: "Xie, Huikai"

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Free, publicly-accessible full text available July 14, 2024
  2. Confocal microscopes and two-photon microscopes are powerful tools for early cancer diagnosis because of their high-resolution 3D imaging capability, but applying them for clinical use in internal organs is hindered by the lack of axially tunable lens modules with small size, high image quality and large tuning range. This paper reports a compact MEMS lens scanner that has the potential to overcome this limitation. The MEMS lens scanner consists of a MEMS microstage and a microlens. The MEMS microstage is based on a unique serpentine inverted-series-connected (ISC) electrothermal bimorph actuator design. The microlens is an aspheric glass lens to ensure optical quality. The MEMS microstage has been fabricated and the lens scanner has been successfully assembled. The entire lens scanner is circular with an outer diameter of 4.4 mm and a clear optical aperture of 1.8 mm. Experiments show that the tunable range reaches over 200 µm at only 10.5 V and the stiffness of the microstage is 6.2 N/m. Depth scan imaging by the MEMS lens scanner has also been demonstrated with a 2.2 µm resolution, only limited by the available resolution target.

     
    more » « less
  3. Laser scanning based on Micro-Electro-Mechanical Systems (MEMS) scanners has become very attractive for biomedical endoscopic imaging, such as confocal microscopy or Optical Coherence Tomography (OCT). These scanners are required to be fast to achieve real-time image reconstruction while working at low actuation voltage to comply with medical standards. In this context, we report a 2-axis Micro-Electro-Mechanical Systems (MEMS) electrothermal micro-scannercapable of imaging large fields of view at high frame rates, e.g. from 10 to 80 frames per second. For this purpose, Lissajous scan parameters are chosen to provide the optimal image quality within the scanner capabilities and the sampling rate limit, resulting from the limited A-scan rate of typical swept-sources used for OCT. Images of 233 px × 203 px and 53 px × 53 px at 10 fps and 61 fps, respectively, are experimentally obtained and demonstrate the potential of this micro-scannerfor high definition and high frame rate endoscopic Lissajous imaging.

     
    more » « less